Interface specifications – Westermo DDW-142-485 User Manual

Page 9

Advertising
background image

9

6642-22511

Interface specifications

Power
Rated voltage

24 to 48 VDC

Operating voltage

19 to 60 VDC

Rated current

245 mA (405 mA) @ 24 VDC (with 500 mA USB load)
124 mA (200 mA) @ 48 VDC (with 500 mA USB load)

Rated frequency

DC

Inrush current, I²t

10.6 mA²s @ 24 VDC
24.7 mA²s @ 36 VDC
42.4 mA²s @ 48 VDC

Startup current*)

2 x Rated current

Polarity

Reverse polarity protected

Redundant power input

Yes

Isolation to

All other

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm² (AWG 24 – 13)
Connect the unit using at least 18 AWG (0.75 mm²) wiring

Shielded cable

Not required

* External supply current capability for proper start-up.

RS-422/485
Electrical specification

EIA RS-422/485

Data rate

50 bit/s – 2 Mbit/s

Data format

7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
(2 stop bits only when no parity is set).

Circuit type

TNV-1

Transmission range

Up to 1200 m / 0.74 mi, depending on data rate and cable
type

Isolation to

Power, I/O realay output, I/O Digital input, SHDSL line,
Ethernet

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm² (AWG 24 – 12)

Shielded cable

Not required, but recommended in railway installations close
to the rails.*

Conductive housing

Yes

* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m

boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port.