Type tests and environmental conditions – Westermo Lynx-x06-F2G User Manual

Page 6

Advertising
background image

6

6643-2250

Type tests and environmental conditions

Environmental phenomena

Basic standard

Description

Test levels

ESD

EN 61000-4-2

Enclosure

Contact: ±6 kV
Air: ±8 kV

Fast transients

EN 61000-4-4

Power port

±2 kV

Signal ports

±2 kV

Earth port

±1 kV

Surge

EN 61000-4-5

Power port

L-E: ±0.5 kV, 12 Ω, 9 μF
L-L: ±0.5 kV, 2 Ω, 18 μF
L-E: ±2 kV, 42 Ω, 0.5 μF
L-L: ±2 kV, 42 Ω, 0.5 μF
L-E: ±2 kV, 12 Ω, 9 μF
L-L: ±1 kV, 12 Ω, 9 μF

Signal ports

L-E: ±1 kV, 2 Ω
L-E: ±2 kV, 42Ω, 0.5 μF

Power frequency magnetic field

EN 61000-4-8

Enclosure

300 A/m; 0, 16.7, 50 Hz

Pulsed magnetic field

EN 61000-4-9

Enclosure

300 A/m

Radiated RF immunity

EN 61000-4-3

Enclosure

10 V/m @ (80 – 800) MHz
20 V/m @ (800 – 1000) MHz
10 V/m @ (1400 – 2100) MHz
5 V/m @ (2100 – 2500) MHz
1 V/m @ (2500 – 2700) MHz
1 kHz sine, 80% AM

Conducted RF immunity

EN 61000-4-6

Power port

10 V, 80% AM, 1 kHz; (0.15 – 80) MHz

Signal ports

10 V, 80% AM, 1 kHz; (0.15 – 80) MHz

Earth port

10 V, 80% AM, 1 kHz; (0.15 – 80) MHz

Radiated RF emission

EN 55022

Enclosure

Class A

FCC Part 15

Class A

Conducted RF emission

EN 55022

Power port

Class B

Signal ports

Class B

Dielectric strength

EN 60950-1

Power port to all
other ports

1.5 kVrms, 50 Hz, 1 min

Signal ports to all
other ports

1.5 kVrms, 50 Hz, 1 min

Environmental

Temperatures

Operating

–40 to +70°C (–40 to +158°F)*

Storage and transport

–50 to +85°C (–58 to +185°F)

Humidity

Operating

5 to 95 % relative humidity

Storage and transport

5 to 95 % relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

10 year

Reliability prediction (MTBF)

MIL-HDBK- 217F Operating

615 000 hours

Vibration

IEC 60068-2-6
(sine)

Operating

3 – 13.2 Hz: 1mm
13.2 – 100 Hz: 0.7 g

5.5 – 30 Hz: 1.5 g
30 – 50 Hz: 0.42 mm
50 – 500 Hz: 4.2 g**

Shock

IEC 60068-2-27

Operating

30 g, 11 ms
100 g, 6 ms**

Bump

IEC 60068-2-27

Operating

10 g, 11 ms

Packaging

Enclosure

EN 60950-1

Zinc

Fire enclosure

Dimension W x H x D
With connectors

52.5 x 100 x 101 mm
52.5 x 119 x 101 mm

Weight

0.7 kg

Degree of protection

EN 60529

Enclosure

IP 40

Cooling

Convection

*

* Refer to “Safety” section.