Connections, Line connection – Westermo MA-47 User Manual

Page 5

Advertising
background image

12

6047-2002

Direction

Pin

CCIT V.11

no.

Description

Receiver

1

A’ (R+)

Receiver

2

B’ (R-)

Transmitter

3

A (T+)

Transmitter

4

B (T-)
Shield

Connections

Line connection
(5-Position screw-terminal)

Direction

Connection

CCITT V.24

Signal name

Code

I

2

103

TD/Transmitted Data

O

3

104

RD/Received Data

I

4

105

RTS/Request To Send

O

5

106

CTS/Clear To Send

O

6

107

DSR/Data Set Ready

7

102

SG/Signal Ground

O

8

109

DCD/Data Carrier Detect

I

20

108/2

DTR/Data Terminal Ready

I = Input O = Output on MA-47

Terminal connection (DCE)
(RS-232-C/V.24/V.28, 25-Polig D-sub, female)

Line connection

1) If shielded cable is used, connect the shield only at one end to avoid ground currents.

Look right for a section of rack RV-01 with
one MA-47 mounted.
Terminal connection to a 25-position D-sub(female) connector on MA-47.
Line connection to a 5-position detachable screw-terminal, which is mounted on the
male connector located at the rear of RV-01.

1

13

25

14

1

2

3

4

5

1 2 3 4 5

Twisted pairs

A’

B’

A

B

Transmitter

Receiver

MA-47

Receiver

Transmitter

Shield

1)

1

2

3

4

5

3

4

5

A/A’

B/B’

Transmitter/

Receiver

A/A’

B/B’

MA-47

Transmitter/

Receiver

2-wire

4-wire

Twisted pairs

RS-422
equipment

A

B

A’

B’

RS-485
equipment

Shield

1)

The definations R+/R–, T+/T– can be various
between different manufactures.

Advertising