Maintenance, Installation, 1 mounting / removal – Westermo RD-48 User Manual

Page 18

Advertising
background image

18

6153-2004

5.  Maintenance

No maintenance is required, as long as the unit is used as 
intended within the specified conditions.

6.  Installation

6.1  Mounting / Removal

Before mounting or removing the unit:
Prevent damage to internal electronics from electrostatic 
discharges (ESD) by discharging your body to a grounding 
point (e.g. use of  wrist strap).
Prevent access to hazardous voltages by disconnecting 
the unit from AC/DC mains supply and all other electrical 
connections.

Mounting
This unit should be mounted on 35 mm DIN-rail which is horizontally mounted on a wall 
or cabinet backplate. 
This unit use convention cooling. To avoid obstructions to the airflow around the unit, 
use the following spacing rules. Recommended spacing 25 mm (1.0 inch) above/below and 
10 mm (0.4 inches) left/right the unit. 
Snap on mounting, see figure

Removal
Press down the black support at the back of the unit 
using a screwdriver, see figure.

Min  

10 mm 

(0.4 inches)

4.4  Mechanics
Dimension (W x H x D) 

55 x 128 x 100 mm

Weight 

0.3 kg

Mounting 

Snap on mounting to 35 mm DIN-rail

Degree of protection 

IP 20 (IEC 529)

CLICK!

25 mm

25 mm