9.  Application example

Normally star networks is not allowed in RS-422/485 applications. Using the RD-48 
makes it possible to create branches up to 1200 m. Observe that the RD-48 should be 
connected a maximum of 30 cm from the bus.
Observe setting of termination and fail-safe.

RD-48

RD-48

RD-48

RD-48

RD-48

RD-48

RD-48

RD-48

RD-48

RD-48

RD-48

RD-48

RD-48

+5V

0V

Line

Termination

and fail-safe

R–

R+

= Termination and fail-safe

Note ! It is not possible to have more than 8 repeaters in serial connection