Fault relay – Westermo RV-07B User Manual

Page 12

Advertising
background image

12

6130-2200

Public Switched Telephone Network (PSTN)

Electrical specification

Public Switched Telephone Network

Data rate

300 bit/s to 33.6 kbit/s

Protocol

B103, B212, V21, V22, V22B, V23C, V32, V32B, V34

Circuit type

TNV-3

Isolation to

Power port

3kV

rms

50 Hz 1 min

PSTN line

2kV

rms

50 Hz 1 min

Leased line

2kV

rms

50 Hz 1 min

RS-422/485

2kV

rms

50 Hz 1 min

RS-232

2kV

rms

50 Hz 1 min

Connection

Screw connector

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Shielded cable

Not required

Leased Line (LL)

Electrical specification

2- or 4-wire Leased Line

Data rate

300 bit/s to 33.6 kbit/s

Protocol

B103, B212, V21, V22, V22B, V23C, V32, V32B, V34

Transmission range

PSTN

30 dB

Leased Line max

40 dB

Protection

Installation Fault Tolerant (up to ±60 V)

Isolation to

Power port

3kV

rms

50 Hz 1 min

PSTN line

2kV

rms

50 Hz 1 min

RS-422/485

2kV

rms

50 Hz 1 min

RS-232

2kV

rms

50 Hz 1 min

Connection

Screw connector

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Shielded cable

Not required

Fault relay*

Relay

Direction Description

Product

marking

1

In/Out

Signal

1

2

In/Out

Normally closed

2

3

In/Out

Normally open

3

4

Not in use

4

* The switch is incorporated with a user configurable fault contact (STAT pins) that enables network and switch

faults to be highlighted, see below.

The fault contact is a potential free, normally closed solid-state component and therefore requires power to

control the device. As standard the fault contact will always highlight Power Supply Failure.