OPERATING MANUAL - TD2 & TD4-25-100 DRYERS

Revision 8/31/01

Page 11

Standard PLC Electrics

Operating this unit is very simple. Once the dryer is
connected to the facility power supply, the unit can be started
by turning the disconnect located on the electrical panel
enclosure to the ON position and pressing the ON button on
the Control Panel Key Pad. To shut the dryer off, simply push
the OFF button on the Control Panel Key Pad and turn the
disconnect to the OFF position.

Setting the process air temperature is done using the Digital
Controller.

For a more detailed explanation, see the following sections.

Control Panel - Operating Display

Turn Power on at dryer using disconnect

1. POWER light indicates power to the unit is on.

Press ON button on key pad

2. Illuminated BLOWER light indicates Blower is on.
3. Flashing IN REGEN light indicates bed is in

Regeneration cycle.

4. Steady IN REGEN light means bed is in cooling cycle.
5. Illuminated REGEN HEATER light indicateS heater is

on.

Alarm Conditions:

6. Flashing PROCESS AIR TEMP. ALARM indicates an

over or under temp alarm.
Unit shuts down.

7. Steady PROCESS AIR TEMP. ALARM light indicates

unit has failed. Further diagnostics are required.

8. Flashing ALARM light indicates a safety override

condition has occurred. Dryer shuts down.

Digital Controller - Setting Process Air Temperature:

Press SET button - temperature set display will flash.

Press up arrow to increase temperature and down arrow to
decrease temperature.

Press SET again to enter the new temperature.

If the display flashes, the temperature is out of the control
range.

If the display shows 0000 the thermocouple is not connected
or is faulty.

START-UP PROCEDURE

XX

XX

ALARM

PROCESS

HEATER ON

TEMP.

PROCESS AIR

ON

OFF

POWER

LEFT

BED

RIGHT

BED

IN REGEN

IN REGEN

PROCESS

BLOWER ON

REGEN
HEATER ON

REGEN
HEATER ON

ALARM