1 –Pump 1-Station Controller

Chapter 6: Troubleshooting

23 of 30

Vacuum leak in the system.

Find the leak and repair it.

Filter in filter chamber is plugged. Clean thoroughly; replace if

worn.

Material receiver filter is plugged. Clean thoroughly; replace if

worn.

Blower is dead-headed.

Check the blower inlet for
obstructions.

Valve(s) not seating properly.

Service valve(s).

Vacuum conveying rates
decline.

Low air pressure.

Verify minimum of 80 psi
(551.6 kPa/5.52 bars) supply air
pressure.