Page 20

8. Click the 'Lighting' button to bring up the following screen. This screen populates itself with the names and cur-

rent status of any lighting devices that have been programmed in the Control with a name and the "Show" option

enabled. Each device has an On/Off indicator as well as a dimming "slider". The slider allows a dimmable light to

be adjusted from 0% (Off) to 100% (full on). The On/Off indicator will be Green when the device is On. If there are

too many lights to fit on one screen the word Next> will illuminate along the bottom of the screen. Click on Next>

to see additional lights or <Prev to back up to the previous group of lights.

Bypass: The bypass key (and # key) can be used to bypass zones. Press 'Bypass', the number of the zone to

bypass and click 'Bypass' again.

Status: The 'Status' button brings up a display of all zones defined in the currently selected area, along with their

status (“Normal”, “Bypassed”, “Violated”) and state (“Short”, “Open”, “EOL”).