Cisterna, Tank, Caricamento mandata dalla pompa – ARAG Mixer NIAGARA User Manual

Page 9

Advertising
background image

9

The chemical is taken from Mixer tank via vacuum as produced by the
Venturi pump under the very device.

The mixer outlet, draining in the tank, must be connected to

the Ø 40 mm fitting (original equipment) or Ø 50 mm fitting
(upon request) through pipes that can withstand a pressure
of at least 5 bar, tightened with suitable clamps.

4.2

Nozzle flowrate

8 mm nozzle

Pressure

Nozzle flowrate

Draining

bar

PSI

(l/min)

(l/sec)

2

29

60

2,0

3

44

74

2,6

4

58

85

3,3

5

73

95

4,1

6

87

100

4,8

7

102

110

5,3

8

116

120

5,8

4.3

System diagram

5 USE

All mixing and cleaning operations should be carried out

when the Mixer is closed.

Should it not be possible, wear all required personal protec-

tive equipment and comply with all safety instructions as

specified onto the pesticide container.
OPERATING THE MANUAL VALVES ON MIXER SIDE WHEN

THE COVER IS OPEN MAY CAUSE SERIOUS ACCIDENTS.

ARAG IS NOT RESPONSIBLE FOR ANY INJURIES TO PE-

OPLE AND ANIMALS OR DAMAGES TO OBJECTS CAU-

SED EITHER BY IMPROPER OR INCORRECT USE OF THE

MIXER OR FAILURE TO OBSERVE GIVEN SAFETY MEASU-

RES.
NEVER leave the Mixer unguarded while feeding water

through one or more valves.

Before starting mixing, position the Mixer following the directions given
by the farming machine manufacture.

Tab. 2a

CONTINUES

caricamento

mandata
dalla pompa

CISTERNA

11 mm nozzle

Pressure

Nozzle flowrate

Draining

bar

PSI

(l/min)

(l/sec)

2

29

125

2,5

3

44

150

2,8

4

58

170

3,2

5

73

182

3,6

6

87

195

4,0

7

102

212

4,3

Tab. 2b

16 mm nozzle

Pressure

Nozzle flowrate

Draining

bar

PSI

(l/min)

(l/sec)

2

29

280

2,9

3

44

320

3,1

4

58

355

3,2

5

73

385

3,3

Tab. 2c

5.1

Adding chemicals

A black

I container flushing

B red

I dissipator/anti-clogging nozzle

C yellow

I internal flushing system

C

B

A

Start the pump deviating the flow towards Mixer delivery at the same
time (Fig. 4),

make sure to comply with flowrate/pressure values

listed in the nozzle tables (tables 2a ÷ 2c).

Fig. 4

Fig. 5

TANK

filling

pump

delivery

Advertising