25

DE
EN

FR

PL

RU

D5

D6

D7

D12

PROTOCOLL

S5-1

S5-2

S5-3

S6-4

On

On

On

Off

F2

Off

Off

Off

On

Philips (Bosch)

Off

Off

On

On

Reserved

Off

On

Off

On

Dynacolor

Off

On

On

On

Reserved

D8

D9

D10

BAUD RATE

S5-4

S6-1

S6-2

Off

Off

Off

2400 bps

Off

Off

On

4800 bps

Off

On

Off

9600 bps

(Default)

Off

On

On

19200 bps

On

Off

Off

38400 bps

D11

PARITY BIT

S6-3

Off

None

On

Even

Note: When used in a Pelco coaxitron control system the default

protocol setting should be used.