Model 7160 HD/SD/ASI/310 Protection DA

Each of the signals is fed to identical detection circuits which evaluate multiple parameters and

characteristics of the signal in order to arrive at a fault decision. Detection of TRS errors is done in a

Receiver/Reclocker circuit which produces a reclocked serial output feeding a Deserializer circuit. The

output of this section then feeds a Field Programmable Gate Array (FPGA) where the signals are vetted,

or tested for configured parameters. The Signal Vetter™ process in the FPGA detects the parameters

chosen by the user using either the front panel controls or through the Avenue PC or Touch Screen

menus. Each of the chosen aspects are monitored independently, and when they fail to meet the

vetted standard, a fault condition is issued. Fault conditions can be monitored with an external alarm

system or other device through the 15-pin Control connector on the corresponding rear backplane

connector. The Form C relays status outputs from this connector can be monitored by a device to

show Primary and Secondary signal status and the current position of the protect switch (Primary or

Secondary).

Two GPI Override Inputs are available to allow changing switch position in response to triggers from

an external source. This can be used to manually reset the switch after the Primary has recovered from

a fault condition or set to respond to a signal state from an external device to trigger a switch.

The on-board CPU can monitor and report module ID information (slot location, software version

and board revision), and power status to the optional frame System Control module. This information

can be accessed by the user or set to register an alarm if desired using the remote control options

available.

Every function and parameter on the module can be controlled from an Avenue Touch Screen Control

Panel or the Avenue PC Control Application. Memory registers can be used to save the complete

configuration of the module, making it easy to change instantly between different configurations.

Modules at software version 2.2.0 or later support SNMP (Simple Network Management Protocol)

monitoring. For each applicable signal processing module, module, signal, and reference status are

reported. For complete details on using SNMP monitoring, refer to the Avenue System Overview in the

manual that accompanies each frame.

7160 HD/SD/ASI/310 Protection DA, portrait layout

Rcvr/EQ

Deserializer

& EDH Processor

Primary

Loopback

Content

Analyzer

Protection

Watchdog

GPI Inputs

Sel Sec

Sel Pri

Switch Position

GPI Override Inputs

Status Logging

Avenue System Control

Secondary Fail

Primary Fail

Common

Serial Port

Form C

Relay

Alarm Outputs

Backplane

Interface

Module Control System

Decision Arbitration

Reclocker

Relay

Rcvr/EQ

Secondary

Loopback

HD/SD

Primary Input

Relay

Protected

Output

(Fail-safe)

Protected

Outputs

(5 each)

HD/SD

Secondary Input

Reclocker