7465 Sync Changeover Switch and 9465 3G Sync Changeover Switch

9465 SC

Out C

Sec B

Out B

Pri A

Pri B

Pri C

Out A

Sec C

Sec A

Control

9465 3RU and 1RU Backplane Diagrams

3RU Backplane

1RU Backplane

PIN

FUNCTION

1

1

6

11

5

10

15

Pri NO

Control

2

Pri NC

3
4

Pri Com

5
6
7
8
9

Prot NC

10

Prot NO

11

Prot Com

12

Pri Sel

13
14

Sec Sel

15

Sec NO

Sec NC

Sec Com

Channel CAES audio,
Composite, Bi-Level Sync,
Tri-Level Sync Ref:

Connect a primary analog
composite, AES digital audio,
Bi-Level Sync or Tri-Level Sync
reference input signal to Pri C.
Connect a secondary analog
composite, AES digital audio,
Bi-Level Sync or Tri-Level Sync
reference input signal to Sec C.
Connect the Channel C output
reference signal from Out C to a
properly terminated distribution
amplifier for feeding the signal
throughout the facility.
NOTE: Tri-Level Sync is available
only in Remote mode.

Channel A – 3G, HD SDI, SD SDI,
ASI, 310:

Connect a primary 3G, HD SDI,
SD SDI input signal to Pri A.
Connect a secondary 3G, HD SDI,
SD SDI input signal to Sec A.
Connect the Channel A output
reference signal from Out A to a
properly terminated distribution
amplifier for feeding the signal
throughout the facility.

IMPORTANT NOTE: All channel output destinations must
be terminated properly. Improper termination will affect the
integrity of the sync signal and cause errors. Be sure any unused
inputs to distribution amplifiers or other destinations are
terminated.

Channel BAES audio,
Composite, Bi-Level Sync,
Tri-Level Sync Ref:

Connect a primary analog
composite, AES digital audio,
Bi-Level Sync or Tri-Level Sync
reference input signal to Pri B.
Connect a secondary analog
composite, AES digital audio,
Bi-Level Sync or Tri-Level Sync
reference input signal to Sec B.
Connect the Channel B output
reference signal from Out B to a
properly terminated distribution
amplifier for feeding the signal
throughout the facility.
NOTE: Tri-Level Sync is available
only in Remote mode.

9465 SC

Control

Out A

Pri A

Out B

Sec B

Sec A

Pri B

Pri C

Sec C

Out C