Page 22

7465 Sync Changeover Switch and 9465 3G Sync Changeover Switch

Gang Menu

The Gang menu shown below allows you to configure the 7465 or 9465 module for operating in a
ganged mode in conjunction with another 7465 or 9465 module in an Avenue frame on the same
AveNet network. Refer to the Applications explanation given earlier in this data pack for more details
on how to gang modules.

• Gang Enable – If not using the module in ganged mode with another 7465 or 9465, set to Off.

For ganged mode, set the module to act as Master or Slave. Note that to operate in ganged
mode, one module must act as a Master and the other ganged 7465 or 9465 modules must be
set to Slave.

• Slave Select – Note that this control is grayed out unless the module is set to Master. When

the module is set to Master, use this control to select which slave you wish to configure (Slave
1, Slave 2 or Slave 3). Once you have selected a slave module, you can adjust settings for it
using the controls Slave Enable, Frame Adr and Slot Number.

• Slave Enable – This control can either be Enabled or Disabled. Enable this control if you want

to operate in ganged mode. If the module is functioning as a slave, the Slave Enable control
will be grayed out.

• Frame Adr – Set the AveNet frame address to point to the ganged 7465 or 9465 module on

the AveNet network. Enter a number from 1 through 1000. Note that the other 7465 or 9465
module must also be configured to point back to the location of this module. A master can
set up to 3 of these (one for each slave), while a slave can set up only one (for the associated
master).

• Slot Number – Set the slot number of the frame where the ganged 7465 or 9465 module is

installed. Select a number from 1 through 10. Note that the other 7465 or 9465 module must
also be configured to point back to the slot number of this module. A master can set up to 3 of
these (one for each slave), while a slave can set up only one (for the associated master).

• Mstr/Slav1 Stat, Slave2 Status, Slave3 Status – The status of the ganged connection will be

reported as “---” (meaning “Off”), No Comm, Pri OK, Pri Failed, Comm OK.