Connection detection interval—Interval at which the OpenFlow switch sends an Echo Request

message to a controller. When the OpenFlow switch receives no Echo Reply message within three
connection detection intervals, the OpenFlow switch is disconnected from the controller.

Reconnection interval—Interval for the OpenFlow switch to wait before it attempts to reconnect to a
controller.

To set OpenFlow timers for an OpenFlow switch:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter OpenFlow instance
view.

openflow instance instance-id N/A

3.

Set the connection detection
interval.

controller echo-request interval
interval-value

By default, the connection
detection interval is 5 seconds.
To reduce the CPU load, H3C
recommends that you set the

connection detection interval to a
large value.

4.

Set the reconnection interval. controller connect interval

interval-value

By default, the reconnection
interval is 60 seconds.

Configuring OpenFlow to support dynamic MAC

addresses

You can configure OpenFlow to support querying and deleting dynamic MAC addresses in MAC-IP flow
tables.
To configure OpenFlow to support dynamic MAC addresses:

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Enter OpenFlow instance
view.

openflow instance instance-id N/A

3.

Configure OpenFlow to

support dynamic MAC

addresses.

mac-ip dynamic-mac aware

By default, OpenFlow prohibits
controllers from querying and

deleting dynamic MAC addresses.
This feature is applicable only to
OpenFlow instances that are in the

VLAN mode.