Local On-board Module Configuration

The local on-board 8990ARC parameter settings are listed in

Table 9

. Refer

also to

Table 8 on page 26

for an overview of each of the parameters and

their default values. The status of some controls can be determined by the
state of the front edge LEDs shown in

Figure 5 on page 12

.

Note

When module power recycles the last setup state is restored. The module
does not revert to a factory or the user default.

To make a configuration setting:

1.

Rotate the Function Switch to the desired function switch position.

2.

Move the paddle switch to the up or down position and hold
momentarily to set the desired function. Note that some functions may
require more than one toggle to be activated.

Table 9. 8990ARC On-board Configuration Functions

Function

Switch

Paddle

Switch Up

Paddle

Switch Down

Function Description

0

--

--

Inactive position

1

16:9 output

4:3 output

Selects output format (aspect ratio).

1

1

Selected output format is indicated by yellow 16:9 or 4:3 LED on front edge of module

2

Decrease 4 > 3 > 2 > 1

Increase 1 > 2> 3> 4

Step through four output conversion modes depending on output format
selected (see

Table 8 on page 26

).

2

2

Selected conversion mode is indicated by yellow Mode LED on front edge of module.

3

Picture position toggle with

wrap:

Right > Center > Left > Right

or

Bottom > Center > Top > Bottom

Center

Move picture position on the monitor to one of three positions depending
on applicable mode—Tilt (top, center, bottom) or Pan (left, center, right).
Positioning mode is determined by the picture conversion mode selected.
Return to Center (paddle down) for reference.

4

WSS/Video Index: Off

WSS/Video Index: On

Enable Wide Screen Signaling/Video Index control. Use position 8 to set
WSS or Video Index Coding mode.

5

0 > 1 > 2 > 3 > 0

0 (none)

Steps through choices for data line selection—none, one, two, or three
lines. Return to 0 (none) for reference.

6

High

Low

Select High or Low V Process (vertical resizing) filtering

7

Blanked

Pass

Blank or pass Vertical Ancillary Data (VANC).

8

Standard WSS (toggle 1X)

VID Off (toggle 2X)

Modified WSS (toggle 1X)

Standard Vid (toggle 2X)
Modified Vid (toggle 3X)

Set WSS/Video Index mode. WSS/Video Index must be turned on with
position 4. Custom modes are only available with web browser.

9

Disable GPI and

Set WSS line to 23

Enable GPI

Dual control: General Purpose Interface (GPI) enable/disable. In the up
position, GPI control is disabled and WSS is set to line 23 default.

A

Recall GPI 1

Save GPI 1

Save/recall GPI 1 mode and current option settings.

B

Recall GPI 2

Save GPI 2

Save/recall GPI 2 mode and current option settings.

C

Recall GPI 3

Save GPI 3

Save/recall GPI 3 mode and current option settings.

D

Recall GPI 4

Save GPI 4

Save/recall GPI 4 mode and current option settings.

E

Recall Last User

Save Last User

Save current or recall last saved user settings.

F

Recall default settings

Decrement WSS line from

13-27 with wrap

Recall factory default settings (listed in

Table 8 on page 26

) and WSS line

selection (choose from line 13 to line 27 with wrap back to line 13).