ADA-1023 Single/Dual Analog Audio Distribution Amplifier

Guide to Installation and Operation

ADA-1023

Page 3 of 4

Operating Parameter Adjustment

The ADA-1023 has operating parameters which may be adjusted
at the controller card interface. After pressing the SELECT
button on the ADA-1023 card, use the keys on the local control

panel (described in the Controller card manual) to step through
the displayed menu and adjust the parameters. The menus are
shown below.


NO SIGNAL DELAY

CONFIGURE ALARM

STATUS

VERSION

OVERLOAD 1

ALARM LEVEL

ALARM REPORT

NO SIGNAL 1

ALARM REPORT

ALARM LEVEL

NONE

, GPI

NONE

, GPI

GREEN, YELLOW, RED, FLASH RED

GREEN, YELLOW, RED, FLASH RED

0, ..., 15, ..., 255 [sec]

REAR PANEL ERROR, OVERLOAD 1, OVERLOAD 2, OVERLOAD 1&2,

NO SIGNAL 1, NO SIGNAL 2, NO SIGNAL 1&2, ALL OK

OVERLOAD 2

ALARM REPORT

ALARM LEVEL

NONE

, GPI

GREEN, YELLOW, RED, FLASH RED

NO SIGNAL 2

ALARM REPORT

ALARM LEVEL

GREEN, YELLOW, RED, FLASH RED

NONE

, GPI

SIGNAL THRESHOLD

-48, -42, -36, -30, -24 [dBu]

OVERLOAD THRESHOLD

-9, ..., +24 [dBu]

SINGLE, DUAL

UC Vxxx

MONITORING

OUT 1

, OUT 2, OUT 1&2

FACTORY DEFAULT

RESTORE







OPERATION (continued)

STATUS menu

Displays status of the different board alarms. The higher-level
alarm is displayed, even if not configured to activate the
STATUS LED. ALL OK indicates an absence of alarms.

REAR PANEL ERROR

Absence of the rear panel or an

incompatibility between the module and the rear panel. The
STATUS led turns on flashing red

OVERLOAD Indicates an internal signal level higher than
the overload threshold (channel indicated 1, 2, 1&2).

NO SIGNAL Indicates an internal signal level lower than the
signal threshold during a user defined period (channel
indicated 1, 2, 1&2).


NO SIGNAL DELAY menu

Signal absence is declared when the level signal is lower than
the signal threshold during the selected period, which can be
adjusted from 0 to 255 s. The default value is set to 15 s.

SIGNAL THRESHOLD menu

The presence signal threshold can be adjusted from -48 to -24
dBu by 6 dBu steps. The default value is -36 dBu S.

OVERLOAD THRESHOLD menu

The overload signal threshold can be set from –9 to +24
dBu. The default value is +24 dBu.

MONITORING menu

Allows the pre-selection of the monitored signal. The
ON/OFF command will come from a monitor module like
the MSB-1121 in slot 20 of the Densité frame.