Grass Valley Apex v.2.0 User Manual

Page 103

Advertising
background image

APEX — Installation and Service Manual

105

Jupiter Control

1.

Install the CC-2010 Matrix (Crosspoint bus) cable.

Interconnection from a Jupiter VM-3000 or CM-4000 control board is
via Crosspoint bus cable, which can be supplied in 3, 10, 25, or 50 foot
lengths.

In multi-frame systems, the Crosspoint bus is connected only to the
chassis containing the CX-34000 Control Crosspoint board(s).

The CC-2010 is a 10-conductor (plus ground) cable. Ready-made cables,
with installed 15-pin D male connectors, are available from Thomson
Grass Valley; see the

Ordering Information

section.

All rear-panel Crosspoint bus connectors are 15-pin D, female.

For those who wish to prepare their own Crosspoint cables, pinouts are
shown in

Figure 48

below. The cable itself should be Belden 9505 or

equivalent. (This diagram references Assembly CC-2010 Matrix cable,
drawing number 01-032707-TAB.) Details concerning ferrite cores are
given in

Figure 49 on page 106

.

Figure 48. Crosspoint Cable Wiring (CC-2010)

1

1

8

P1

DB15P

(male)

Shield (drain)

P2

DB15P

(male)

Red

9

Black

2

Yellow

10

Black

3

Green

11

Black

4

Blue

12

Black

5

White

13

Black

8

2

3

4

5

9

10

11

12

13

Twisted pairs

50 ft ( 15.2 m) max

Ferrite core

Ferrite core

Shield

Red

Black

Yellow

Black

Green

Black

Blue

Black

White

Black

Reset

Data

Clock

Take

Confirm

Ground