Gecko Frames — Instruction Manual

59

Video Frame

The conditions monitored by SMPTE Alarm reporting are:

Frame Health

Power supply 1 voltage

Power supply 2 voltage

Fan rotation

Frame temperature

Module Health (capability module dependent, refer to specific module
instruction manual).

Power supply voltage

Signal present at input

EQ warning

EDH Monitoring (capability module dependent, refer to specific
module instruction manual).

EDH error detected

The impedance between the center conductor and shield of J101 can be in
one of two states:

Open – less than100 μA of current will flow, and

Closed – less than 2 V will appear from center conductor to shield with
less than 20 mA of current flowing.

There are three operational conditions (capability is module dependent,
refer to specific module instruction manual):

Open – no faults,

Closed – there is an internal fault, and

Pulsing – there has been a signal error detected in one of the modules.

In addition to fault reporting through the SMPTE Alarm connector, there is
a RED Fault LED on the Frame Monitor and 8900NET Network Interface
modules that is visible through the Fault window of the 8900TF/TFN front
cover. This LED is OFF when no fault conditions are detected and ON when
either an internal fault or a signal error is detected.

A number of frames can be coupled together as one alarm circuit by using
a T-connector. Refer to

Figure 22 on page 60

for a typical alarm circuit inter-

connect diagram.