JEP-100 — Installation and Operating Manual

55

Operation

Defining a Level Button

Any group of the "96 buttons" can be assigned to individual levels,
allowing the operator to toggle buttons on and off during a split switch.

1.

Press CLEAR.

This returns the panel to the "home state."

2.

(Optional) Check the desired key position for the level:

a.

PRESET - ON.

b.

Press the key you would like to use. Check the Preset window for
the current assignment.

c.

Repeat if necessary to find a suitable location.

d.

PRESET - OFF.

3.

ASSIGN/SELECT - ON

4.

LEVEL - ON.

5.

Use the UP/DOWN buttons to select the level.

The name of the level is shown in the Level window.

6.

Press the desired button.

The Level is now assigned to the button.

The button will illuminate to show that the level is selected for
switching.

For level breakaway instructions, see

page 50

.

The top six function buttons on the right side of the panel can also be used
for levels but only when Alternate mode is active (see

page 63

).

Note

A level button assignment always refers to a row number in the CP Level Set
table. If the table is changed such that the row number points to a different
level, the level button will now select the new level.