Specifications, Appendix a — specifications, Appendix – Grass Valley K-Frame Installation Planning Guide Jul 07 2014 User Manual

Page 49

Advertising
background image

K-FRAME — Installation Planning Guide

49

Appendix

A

Specifications

Table 1. K-Frame Video Standards

3G Modes

1080p50/59.94/60, Level A and Level B

SMPTE 424M-2006

HD Modes

1080i 29.97/30

SMPTE 274M Table 4, 5

1080i 25

SMPTE 274M Table 6

1080psf 23.976/24/25/29.97/30

SMPTE RP211 Table 12-16

720p 50/59.94/60

SMPTE 296 Table 1-3

SD Modes

525i 29.97

SMPTE 259M

625i 25

SMPTE 259M

Table 2. K-Frame Mechanical Specifications

Component

Depth

Width

Height

Weight

a

a

All weights approximate.

Rack Units

Compact 6-RU K-Frame

558.8 mm
(22.0 in.)

482.8 mm
(19 in.)

266 mm
(10.47 in.)

31.1 kg
(68.2 lbs.)

6

Standard 13-RU K-Frame

566.2 mm
(22.29 in.)

482.8 mm
(19 in.)

577.1 mm
(22.72 in.)

55.1 kg
(121.0 lbs.)

13

Power Supply Frame

492 mm
(19.37 in.)

483.1 mm
(19 in.)

44.0 mm
(1.75 in.)

10.5 kg
(23.0 lbs.)
Above for two PS modules.
A single module weighs 2.5
kg (5.4 lbs.). Up to three
modules supported.

1

Table 3. Environmental

Storage temperature

-20 to 70 deg C (-4 to 158 deg F)

Operating temperature

0 to 40 deg C (32 to 104 deg F)

Relative humidity

0-95% (non-condensing)

Electromagnetic environment

E2 (according to EN55103-1, -2)