Communication port specifications, Reference port specifications, Specifications – Grass Valley NV5256 v.1.8 User Manual

Page 49

Advertising
background image

NV5256 Machine Control Router • User’s Guide

41

6. Specifications

Communication Port Specifications

Communication Port Specifications

Table 6-6. Communications Port and Related Specifications for the NV5256

Reference Port Specifications

Table 6-7. NV5256’s Reference Port Specifications

Parameter

Specification

Serial communication
ports

One primary DE9 female (CTRL1) and one secondary DE9 female (CTRL2) RS-
422 receptacles for each control card (4 in total).
Ports comply with the SMPTE 207M standard.
Signalling protocol and communication parameters are software-dependant.

Ethernet ports

One RJ-45 connector (10/100baseT) for each control card (2 in total).
Connection speed is auto-negotiated. Port employs NVISION Ethernet protocol.
One BNC connector adhering to 10base2 specification for each control card (2 in
total). Connection shared between controllers. Use for inter-frame expansion

only.

Diagnostic ports

One DE9 female diagnostic connector for each control card (2 in total).

Rear panel

Software configured for RS-232 (default) or RS-422 interface specification.

Front edge of control
card

RS-232 (9600, 8, N, 1)

Alarm ports

One DE9 female receptacle (system-level alarms).
One 3-pin Phoenix receptacle (power supply alarm).

Parameter

Specification

Video reference ports

2 looping BNC input pairs, one for each installed control module. External

terminators are required.
Ports accept NTSC, PAL or HD tri-level reference signals. Inputs may be of

differing rates. Redundant and dual modes are supported.
Return Loss > 30dB to 5MHz.

AES reference ports

2 BNC input receptacles, one for each installed control module. Ports accept
AES3id format signals at 48kHz sample rate
OR
2 Phoenix twisted pair screw terminal blocks, one for each installed control

module. Phoenix ports accept AES3 format signals at 48kHz sample rate.
Note: only one connector type may be used on each AES reference input.
24-bit silence.
Locked to the control card’s 24.576MHz clock.

Time-code reference
port

Not used.