Start NetCentral Lite monitoring software

34

PVS 3000 & PVS3500 Installation Guide

23 February 2004

Adding the PFR 500, PFR 600, or PFR 700 RAID storage device

This procedure explains how to add the PFR500, PFR600, or PFR700 Fibre Channel
RAID Chassis to the NetCentral device list. This step is required in order to monitor
the RAID chassis.

NOTE: This step is not required for the PFC500 Fibre Channel RAID Chassis
since it is monitored in-band through the Profile XP Fibre Channel connection.

To add the PFR500, PFR600, or PFR700 RAID storage chassis to the device list:

1. In the NetCentral main menu, click

File | Add Device

.

2. In the Add Device dialog box, enter the IP address or host name for RAID

Controller A, then click

OK

. You can use the following default address if you have not

modified network settings: controller A = 192.168.0.11.

NetCentral contacts RAID Controller A, and adds it to the device list. The RAID
Controller is labeled using the controller IP address or the host name if network
name resolution is setup for the Profile XP system. (Refer to “Setting up a simple
network” in the Profile XP System Guide.)

3. Repeat step 1 and step 2 for RAID Controller B, if installed. You can use the

following default address if you have not modified network settings: controller B =
192.168.0.12.

4. Refer to the Profile XP Service Manual for information on using NetCentral Lite

monitoring software.