5 troubleshooting guide – Grass Valley RCP-10x0 User Manual
Page 26
Advertising
GUIDE TO INSTALLATION AND OPERATION
22 | RCP-10x0
5 Troubleshooting
Guide
Here is what to do when you have a problem communicating between an HRS-1801 and an RCP-10x0.
Please follow ALL the steps in order.
5.1 Initial
setup
1. Connect the RCP-10x0 as depicted below:
PoE Power
Injector
Straight Ethernet cable
Computer
IN
OUT
CROSSOVER Ethernet cable
AC
IP parameters of this computer:
IP Address : 192.168.100.200
Subnet mask : 255.255.255.0
Gateway : 192.168.100.1
DIP Switch settings:
CONFIG mode
ROUTER mode
Make sure the Ethernet cable between the PoE Power Injector and the computer is a crossover cable.
2. Set the IP parameters of the computer as follow (Windows XP shown):
Advertising