To install the SSP-3801 card, follow these steps:

1 Open the front panel of the frame.

2 Slide the SSP-3801 card into the slot and push gently on the

Ejector

handle to seat the

connectors (figure

3-2

).

The card should be inserted into the far left slot associated with the SSP-3801’s 4-slot
rear panel. If you insert the card into the wrong slot, the on-card status LED will flash
red to indicate that there is no connection to the rear panel.

Ensure that the card is in the correct slot to prevent damage to itself or other hardware
in the frame.

Figure 3-2. Inserting the SSP-3801 card into the Densité 3 frame

3 Close the front panel of the frame.

Note:

To remove an existing SSP-3801 card from the slot, tilt up the
swivel handle on the front of the card to lever the connectors
apart, then use the handle to pull the card straight out of the
slot.

Input/Output slots

Power and Densité 3
communication slot