Grounding requirements for personnel, N in – Grass Valley Trinix Back-Up Power Supplies Nov 16 2012 User Manual

Page 27

Advertising
background image

Trinix — Installation and Service Manual

27

ESD Protection

Grounding Requirements for Personnel

The information in this section is provided to assist you in selecting a
grounding method. This information is taken from ANSI/ESD S20.20-2007
(Revision of ANSI/ESD S20.20-1999).

Product qualification is normally conducted during the initial selection of
ESD control products and materials. Any of the following methods can be
used: product specification review, independent laboratory evaluation, or
internal laboratory evaluation.

* For situations where an ESD garment is used as part of the wrist strap
grounding path, the total system resistance, including the person, garment,
and grounding cord, must be less than 3.5 x 10

7

ohm.

Table 1. Product Qualification

Personnel Grounding Technical

Requirement

Test Method

Required Limits

Wrist Strap System*

ANSI/ESD S1.1 (Section 5.11)

< 3.5 x 10

7

ohm

Flooring / Footwear System – Method 1

ANSI/ESD STM97.1

< 3.5 x 10

7

ohm

Flooring / Footwear System – Method 2
(both required)

ANSI/ESD STM97.1

ANSI/ESD STM97.2

< 10

9

ohm

< 100 V

Table 2. Compliance Verification

Personnel Grounding Technical

Requirement

Test Method

Required Limits

Wrist Strap System*

ESD TR53 Wrist Strap Section

< 3.5 x 10

7

ohm

Flooring / Footwear System – Method 1

ESD TR53 Flooring Section and ESD
TR53 Footwear Section

< 3.5 x 10

7

ohm

Flooring / Footwear System – Method 2
(both required)

ESD TR53 Flooring Section and ESD
TR53 Footwear Section

< 1.0 x 10

9

ohm

Advertising