Specifications – Grass Valley Triton Plus Revision 3 User Manual

Page 23

Advertising
background image

Triton Plus - Control Panels - User Manual

23

Specifications

Specifications

Note

All specifications are subject to change without notice.

Table 15. Triton Plus Control Panel Specifications

Parameter

Value

Mechanical

Dimensions

• HxWxD = 44x483x50mm (19 in., 1 RU)

• HxWxD = 88x483x50mm (19 in., 2 RU)

• HxWxD = 176x483x50mm (19 in., 4 RU)

Safety/Emission standards

Compliant with CE EN55103-1 and 2

Power Supply

TPS-PWR-40

40W power supply unit for 8x8 to 32x32

AC supply voltage range

100-240VAC, 50-60Hz max 1.6A

AC mains connector

IEC 320

DC output

• +15V, max. 2.2A/-15V, max 1.35A.

• Maximum 43W for 8x8–32x32 versions

DC connector

DB9, female

Status monitoring

Via LED in front of router/CP

Control

Standard Features

Serial port

RS-232 for protocol conversion, to Triton Plus compact control protocol, or
to 3rd party protocols

Connector

DB9, female

NCB ports

For integration with Triton Plus compact router configuration

Connectors (2)

RJ45 (1 in/1 out)

Ethernet port

10/100BaseT Ethernet is not supported at this time

Connector

RJ45

Environmental

Equipment will meet guaranteed performance specifications under the following conditions:

Operating room temperature range

0º C to 45º C

Operating relative humidity range

< 95% (non-condensing)

Equipment will operate without damage under the following conditions:

Temperature range

-10º C to 55º C

Relative humidity range

< 95% (non-condensing)