The control panel and sidepanel remember the IP address where they are connec-
ted and attached. There is one attachment that is now wrong:
Sidepanel 2 <–> Control Panel 1.
This MUST be corrected in the startup-menu of Sidepanel 2. (Detach from 73 and
Attach to 83).

Also re-inforce the attachment between Sidepanel 1 and Control Panel 1. (Detach
from 73 and Attach to 73 again).

In such a system it may be useful to avoid a mis–attachment totally. And enforce
that the control panel and sidepanel that are mounted in one tub are attached to
each other.

There are two ways to do so:

a) On software installation (of DS0203 or DS0103)

– select ”SinglePanel” installation
– on the next page enter the (complete) IP address of the control panel.
as result there will be no ”Panel” softkey in the StartUp menu.

b) In the registry

the key ”AttachToCp” in
HKEY_CURRENT_USER\Software\BTS\SP\LAN is a string value.

Legal strings are
”NONE” (= do not attach to any control panel)
”EVERY” (= the ”Panel” softkey is present and allows detach and attach)
”192.168.0.xxx” (= the IP address of the control panel to permanently attach to).

6. Now connect to the appropriate mainframe.

The connections shown in the drawing can be useful – for two operator shows
or if mainframe 2 is there for emergency backup.

5.1.5.3

Stored Applications

Applications that are stored in sidepanel 1 (the one with the original IP address) can
be loaded into switcher 1 and will load fine.

Applications that are stored in sidepanel 2 (the one with the changed IP address)
can be loaded.

BUT without precaution they will load into the connected mainframe and control pa-
nel 1 and NOT control panel 2!

It is strongly recommended to use the Change device function the menu Config-
Copy-Simple
to correct that.