Maintenance, Battery, Battery charging (conventional battery) – Polaris 2015 Polaris M1400 User Manual

Page 79: Battery charging (sealed battery)

Advertising
background image

77

MAINTENANCE

Battery

Battery Charging (Conventional Battery)

1. Remove the battery from the vehicle to prevent damage from leaking or spilled

electrolyte during charging. See page 75.

2. Charge the battery with a charging output no larger than 1/10 of the battery’s amp/hr

rating. Charge as needed to raise the specific gravity to 1.270 or greater.

3. Reinstall the battery. See page 76. Make sure the positive terminal is toward the driver’s

side of the vehicle.

Battery Charging (Sealed Battery)

The following battery charging instructions apply only to the installation of a sealed battery.
Read all instructions before proceeding with the installation of this battery.

The sealed battery is already filled with electrolyte and has been sealed and fully charged at
the factory. Never pry the sealing strip off or add any other fluid to this battery.

The single most important thing about maintaining a sealed battery is to keep it fully
charged. Since the battery is sealed and the sealing strip cannot be removed, you must use a
voltmeter or multimeter to measure DC voltage.

WARNING! An overheated battery may explode, causing severe injury or death. Always watch
charging times carefully. Stop charging if the battery becomes very warm to the touch. Allow it to cool
before resuming charging.

For a refresh charge, follow all instructions carefully.

1. Check the battery voltage with a voltmeter or multimeter. A fully charged battery will

register 12.8 V or higher. If the voltage is less than 12.8 volts, recharge the battery at 1.2
amps or less until battery voltage is 12.8 or greater.

2. When using an automatic charger, refer to the charger manufacturer's instructions for

recharging. When using a constant current charger, use the guidelines below for
recharging.

Always verify battery condition before and 1-2 hours after the end of charging.

State of

Charge

Voltage

Action

Charge Time

(Using constant current

charger @ standard amps

specified on top of battery)

100%

12.8-13.0 volts

None, check at 3 mos. from date of

manufacture

None required

75%-100%

12.5-12.8 volts

May need slight charge, if no charge

given, check in 3 months

3-6 hours

50%-75%

12.0-12.5 volts

Needs charge

5-11 hours

25%-50%

11.5-12.0 volts

Needs charge

At least 13 hours,

verify state of charge

0%-25%

11.5 volts or less

Needs charge with desulfating charger

At least 20 hours

Advertising