Connections, 7 connections – HEIDENHAIN TNC 122 Technical Manual User Manual

Page 11

Advertising
background image


10

TNC 122

7 Connections

4/97

7 Connections

L1 N

X41(EXT)

X21

B

X1

X2

X3

X51

1

2

3

4

5

6

7

8

9

10 11 12 13 14

15 16 17 18 19 20 21 22 23 24

25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

NC xxx xxx xx

PLC xxx xxx xx

X1 = Encoder 1
X2 = Encoder 2
X3 = Encoder 3

X21 = RS-232-C/V.24 data interface

X41 = PLC inputs/PLC outputs/analog output/feed rate override/24 V PLC
X51 = Power supply

B = Signal ground

Danger to internal components!

Do not engage or disengage any connections while the unit is under power.

Interfaces X1, X2, X3, X21 comply with the recommendations in EN 50 178 for separation
from line power.

The outputs at connection X41 are metallically isolated from the device electronics by
means of optocouplers.