123

II – 7 Input and output of par

a

met

e

r list and er

ro

r

compensation table

ND 287 with two rotary encoders connected to inputs X1 and X2
(optional)

Parameter

Meaning

#

Start character (#)

ND-287 2

DEG

Model: ND-287, Unit of measure: DEG, DMS or rad

P01

LINEAR =

0

Unit of measure for linear dimensions: mm = 0, inches = 1

P02

ANGULAR =

0

Unit of measure for angular dimensions: DEG = 0, DMS = 1, rad = 2

P03.1 ENC. TYPE =

1

X1: Encoder type: linear = 0, rotary = 1

P03.2 ENC. TYPE =

1

X2: Encoder type: linear = 0, rotary = 1

P04.1 ENC. SIGNAL =

1

X1: Encoder signal: 0 = 11 µA, 1 = 1 Vpp, 2 = Endat, 3 = ANALOG

P04.2 ENC. SIGNAL =

1

X2: Encoder signal: 0 = 11 µA, 1 = 1 Vpp, 2 = Endat, 3 = ANALOG

P05

AXES DISPL. =

0

Display: 0 = X1, 1 = X2, 2 = X1 + X2, 3 = X1 - X2, 4 = f(X1,X2)

P06.1

ANGLE =

0

X1: Angle format: 0 = +/– 180°, 1 = 360° , 2 = +/– infinity

P06.2

ANGLE =

0

X2: Angle format: 0 = +/– 180°, 1 = 360° , 2 = +/– infinity

P10.1 SCALING =

0

X1: Scaling: 0 = off, 1 = on

P10.2 SCALING =

0

X2: Scaling: 0 = off, 1 = on

P11.1 SCL. FACTOR = + 1.000000

X1: Scale factor = 1.000000 (default setting)

P11.2 SCL. FACTOR = + 1.000000

X2: Scale factor = 1.000000 (default setting)

P20 BRIGHTNESS =

94

Brightness of LCD screen: 0 - 100 % (80 % is the default setting)

P21

DISP. SAVER =

1

Screen saver: 0 = off, 1 = on

P22 SAVER TIME =

120

Idle time before screen saver is activated: 120 min

P23 START.DISPL. =

1

Power-up screen: 0 = off, 1 = on

P24

SOFTKEY.X12 =

10101

Display mode selectable with SOFTKEY X1/X2: 11111 = all activated

P30.1 DIRECTION =

0

X1: Count direction: 0 = positive, 1 = negative

P30.2 DIRECTION =

0

X2: Count direction: 0 = positive, 1 = negative

P31.1 SIGN.PERIOD =

20

X1: Signal period: 20 µm (10 µm is the default setting)

P31.2 SIGN.PERIOD =

20

X2: Signal period: 20 µm (10 µm is the default setting)

P32.1

SP/R =

36000

X1: Signal periods per revolution: 36000 is the default setting

P32.2

SP/R =

36000

X2: Signal periods per revolution: 36000 is the default setting

P33.1 COUNT MODE =

5

X1: Counting mode: 0 - 5 = 5, 0 - 2 = 2, 0 - 1 = 1

P33.2 COUNT MODE =

5

X2: Counting mode: 0 - 5 = 5, 0 - 2 = 2, 0 - 1 = 1