20

I Working with the ND 287 position display unit

I – 2 F

undamentals of positioning

Reference marks

Encoders normally contain one or more reference marks (see Fig. I.9)

which the ND 287's reference mark evaluation feature uses to re-

establish datum positions after a power interruption. There are two

main options available for reference marks: fixed and distance-coded.
Encoders with distance-coded reference marks have marks

separated by a specific encryption pattern that allows the ND 287 to

use any two pair of marks along the length of the encoder to re-

establish the prior datums. This configuration means that the operator

only has to travel a very short distance, anywhere along the encoder,

to re-establish the datums when the ND 287 is turned back on.
Encoders with fixed reference marks have one or more marks on

fixed intervals. To re-establish the datums correctly, it is necessary to

use the same exact reference mark, during the reference mark

evaluation routine, that was used when the datum was first

established.

Fig. I.9

Linear scales – with distance-coded

reference marks (upper illustration) and one

reference mark (lower illustration)

Danger to workpiece!

The established datums cannot be restored from one

power cycle to the next if the reference marks were not

crossed before the datums were set.