Suppressing touch probe monitoring: m141 – HEIDENHAIN TNC 128 (77184x-01) User Manual

Page 256

Advertising
background image

256

Programming: Miscellaneous functions

9.4 Miscellaneous functions f

o

r cont

our

ing beha

vior

Suppressing touch probe monitoring: M141

Standard behavior

When the stylus is deflected, the TNC outputs an error message as
soon as you attempt to move a machine axis.

Behavior with M141

The TNC moves the machine axes even if the touch probe is
deflected. This function is required if you wish to write your own
measuring cycle in connection with measuring cycle 3 in order to
retract the stylus by means of a positioning block after it has been
deflected.

Effect

M141 is effective only in the block in which it is programmed.

M141 becomes effective at the start of block.

Danger of collision!

If you use M141, make sure that you retract the touch
probe in the correct direction.

M141 functions only for movements with straight-line
blocks.

Advertising