8

Center in 1st axis

Q321 (absolute value): Center of

the stud in the reference axis of the working plane.

8

Center in 2nd axis

Q322 (absolute value): Center of

the stud in the minor axis of the working plane. If you
program Q322 = 0, the TNC aligns the hole center to
the positive Y axis. If you program Q322 not equal to
0, then the TNC aligns the hole center to the nominal
position.

8

Nominal diameter

Q262: Approximate diameter of the

stud. Enter a value that is more likely to be too large
than too small.

8

Starting angle

Q325 (absolute): Angle between the

reference axis of the working plane and the first touch
point.

8

Stepping angle

Q247 (incremental): Angle between

two measuring points. The algebraic sign of the
stepping angle determines the direction of rotation
(- = clockwise) in which the touch probe moves to the
next measuring point. If you wish to probe a circular
arc instead of a complete circle, then program the
stepping angle to be less than 90°.

X

Y

Q322

Q321

Q262

Q325

Q247

X

Z

Q261

Q260

MP6140

+

Q320

The smaller the angle, the less accurately the TNC can
calculate the datum. Minimum input value: 5°.