2 a u to matic d at u m set ting – HEIDENHAIN TNC 426B (280 472) Touch Probe Cycles User Manual

Page 59

Advertising
background image

HEIDENHAIN TNC 426, TNC 430

47

3.2 A

u

to

matic D

at

u

m Set

ting

U

U

U

U

Center in 1st axis

Q321 (absolute value): Center of

the stud in the reference axis of the working plane.

U

U

U

U

Center in 2nd axis

Q322 (absolute value): Center of

the stud in the minor axis of the working plane.

U

U

U

U

First side length

Q323 (incremental value): Stud

length, parallel to the reference axis of the working
plane

U

U

U

U

Second side length

Q324 (incremental value): Stud

length, parallel to the secondary axis of the working
plane.

U

U

U

U

Measuring height in the touch probe axis

Q261

(absolute): coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made.

U

U

U

U

Setup clearance

Q320 (incremental): additional

distance between measuring point and ball tip. Q320
is added to MP6140.

U

U

U

U

Clearance height

Q260 (absolute): coordinate in the

touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.

U

U

U

U

Traversing to clearance height

Q301: definition of

how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points

U

U

U

U

Datum number in table

Q305: Enter the datum

number in the table in which the TNC is to save the
coordinates of the stud center. If you enter Q305=0,
the TNC automatically sets the display so that the
new datum is on the stud center.

U

U

U

U

New datum for reference axis

Q331 (absolute):

coordinate in the reference axis at which the TNC
should set the stud center. Basic setting = 0

U

U

U

U

New datum for minor axis

Q332 (absolute):

coordinate in the minor axis at which the TNC should
set the stud center. Basic setting = 0

Example: NC blocks

5 TCH PROBE 411 DATUM OUTS. RECTAN.

Q321=+50 ;CENTER IN 1ST AXIS

Q322=+50 ;CENTER IN 2ND AXIS

Q323=60 ;1ST SIDE LENGTH

Q324=20 ;2ND SIDE-LENGTH

Q261=-5 ;MEASURING HEIGHT

Q320=0 ;SET-UP CLEARANCE

Q260=+20 ;CLEARANCE HEIGHT

Q301=0 ;TRAVERSE TO CLEAR HEIGHT

Q305=0 ;NO. IN TABLE

Q331=+0 ;DATUM

Q332=+0 ;DATUM

Advertising