14.8 D

a

tum set

ting with a t

o

uc

h pr

obe

Using touch probe functions with mechanical
probes or dial gauges

If you do not have an electronic touch probe on your machine, you can

also use all the previously described manual touch probe functions

(exception: calibration function) with mechanical probes or by simply

touching the workpiece with the tool.
In place of the electronic signal generated automatically by a touch

probe during probing, you can manually initiate the trigger signal for

capturing the probing position by pressing a key. Proceed as follows:

Select any touch probe function by soft key

Move the mechanical probe to the first position to be

captured by the TNC

Confirm the position: Press the actual-position-

capture key for the TNC to save the current position

Move the mechanical probe to the next position to be

captured by the TNC

Confirm the position: Press the actual-position-

capture key for the TNC to save the current position

If required, move to additional positions and capture

as described previously

Datum

: In the menu window, enter the coordinates of

the new datum, confirm with the SET DATUM soft

key, or write the values to a table (see "Writing the

measured values from touch probe cycles in datum

tables", page 491, or see "Writing the measured

values from touch probe cycles in the preset table",

page 492)

To terminate the probe function, press the END key