Comparison: differences in test run, functionality, Comparison: differences in test run, operation – HEIDENHAIN TNC 620 (340 56x-03) ISO programming User Manual

Page 472

Advertising
background image

472

Comparison: Differences in Test Run,
functionality

Comparison: Differences in Test Run, operation

Function

TNC 620

iTNC 530

Display of delta values DR and DL from
TOOL CALL

block

Are not considered

Are considered

Test Run up to block N

Function not available

Function available

Calculation of machining time

Each time the simulation is repeated by
pressing the START soft key, the
machining time is totaled

Each time the simulation is repeated by
pressing the START soft key, time
calculation starts at 0

Function

TNC 620

iTNC 530

Arrangement of soft-key rows and soft
keys within the rows

Arrangement of soft-key rows and soft-keys varies depending on the active screen
layout.

Zoom function

Each sectional plane can be selected by
individual soft keys

Sectional plane can be selected via
three toggle soft keys

Character set for PROGRAM screen
layout

Small character set

Medium character set

Performing a Test Run in Single block
mode, switching to the Programming
mode of operation at any time

When you switch to the Programming
mode of operation, the warning No
write permission

is displayed; once a

change has been made, the error
message is cleared and the program is
reset to the beginning when you switch
back to Test Run mode.

The operating mode can be switched.
Changes to the program do not
influence the position of the cursor.

Machine-specific miscellaneous
functions M

Lead to error messages if they are not
integrated in the PLC

Are ignored during Test Run

Displaying/editing the tool table

Function available via soft key

Function not available

Advertising