4.5.

[Write] Function

This function allows the parameter information of the selected file to be uploaded into the
CopyUnit.

4.5.1.

How to start up this function

There are the following three methods for the user to startup this function.

● Select [Communication]-[Write] menu on the menu bar.

● Select [

] button of the Operation Panel.

● Select [

] button on the Tool Bar.

4.5.2.

Communication Process

Validity Check


Before writing process starts, the validity of the selected file will be checked.

File extension is not a *.icf
In this case, [Write] button and [Edit] button will be non-activity, and the contents of the
selected file is not shown in the [Selected File]-[Parameter Information] field.

In case of wrong file format
If the format of the selected *.icf file is different with the standard format, [Write] button
and [Edit] button will be in an active status. If click [write] button, the following error
message will be displayed.

In this case only the selected file name can be shown in [File Name] blank.




In case selected file is corrupt
When corrupt data is found in the area of the selected *.icf file where the copy unit
information is stored, the parameter information of the selected file can be shown in the
“Selected File” field, and the “Write” button and “Edit” button can be in an active state.
The following error message will be displayed.