Subject: Example Code Manual

Product: MP2000iec

Doc#: EM.MCD.09.095

Title: Example Code Manual for Linear Flying Shear on MP2300Siec Sigma-5 Demo using camming

July 13, 2009

Page 7 of 21

Figure 6: Multiple continuous registrations at unequal intervals

Figure 7 is an illustration of a first part detection or part detection after a cam out. It can be seen that at part

detection, the master position is 32 degrees. Sensor to home distance is 180 degrees. This means that the cam

cycle will have to start when the actual master position is 32 + 180 = 212 degrees. This first part shift can be

seen in Figure 7. If a part is not detected in the window area, a cam out is commanded and after the cam out is

done, a phase shift to negate all cumulative phase shifts is carried out so that the total shift becomes zero and