Yaskawa Remote Serial Communication Controller LAN Node PCB for use with Microtrac DSD LAN User Manual

Page 18

Advertising
background image

18

RD 790-30

EX2.3. Drive #1 responds with Display Variable ASCII Response message. The data sent over
the serial port from the RSC to the external device is as follows (in the given order):

001H 0FEH 030H 001H 023H

|

|

|

|

Start of message sequence (SOH, NOT SOH)——— 001H 0FEH |

|

|

Length, 48 bytes———————————————————————030H

|

|

Drive #1——————————————————————————————001H

|

Message Type 023H, Display Variable ASCII Response———————————023H

00AH

|

RDU #10———————————————————————————————— 00AH

020H 020H 020H 04CH 049H 04EH 045H 020H
053H 050H 045H 045H 044H 020H 020H 020H

|

Bottom Line ASCII Text——————————— “ LINE SPEED ”

043H 04FH 041H 054H 045H 052H 020H 020H
020H 020H 020H 020H 020H 046H 050H 04DH

|

Top Line ASCII Text—————————————“COATER FPM”

044H 07AH 000H 000H

|

Upper Limit, floating pt value of 1000 ——————————— 0447A0000H

000H 000H 000H 000H

|

Lower Limit, floating pt value of 0 ————————————— 000000000H

000H 000H 000H 000H

|

Initial Value, floating pt value of 0 ————————————— 000000000H

016H

|

Checksum————————————————————————————————016H

Advertising