pins on the connector is as follows:

J4

SIGNAL

PIN # NAME

DESCRIPTION

1 DCD

Data Carrier Detect.
From RSC. A positive
voltage is always pro-
vided on this pin to
resolve the external
device's needs if
necessary.

2 RXDATA

Receive Data. From
RSC. Serial data is
sent from the RSC to
the external device
through this pin.

3 TXDATA

Transmit Data. To
RSC. Serial data is
sent from the external
device to the RSC
through this pin.

4 NC No connection

5 COM

Common. Signal
ground.

6 DSR

Data Set Ready. From
RSC. A positive volt-
age is always provided
on this pin to resolve
the external device's
needs if necessary.

7 RTS

Request To Send. To
RSC. A negative volt-
age on this pin will
prevent the RSC from
sending data to the
external device.

8 CTS

Clear To Send. From
RSC. A negative volt-
age on this pin indi-
cates that the RSC is

not ready to receive
data from the exter-
nal device.

9 NC

No connection.

LED

There is an LED on the RSC (DS1) that is

used to indicate the operating status of the RSC.

OPERATIONAL DESCRIPTION

LED STATES

The LED on the RSC is used to indicate

the operating status of the RSC. The way in
which the LED gives its status is as follows:

RSC OPERATING

LED STATE

STATUS

On, steady

Power is applied, and
the RSC software is
executing.

On, blinking Power is applied, the

RSC software is
executing, and the
RSC is receiving LAN
messages.

Off

Power is not applied, or
power is applied and the
RSC has experienced a
fault and has halted
execution.

RS-232 SERIAL PORT

RS-232 Serial Port Paramaters

The RSC has parameters which

determine the speed and format of the serial

RD 790-30