System LEDs

The System LEDs indicate the switch’s status, independent of the port LEDs.

System LEDs

Indication

Fault
(yellow LED)

• When lit, one or more of the ports has failed or the internal temperature has

exceeded acceptable levels.

• When flashing, all ports are operational but another error has occurred. Errors

appear in an event log. The level of error severity that will cause flashing to start
can be controlled using the config sys fault command in the CLI. The default is
level 3, Critical.

Note: Whether lit or flashing, the switch will continue to operate. Switch

functionality may be impaired depending on the event that triggered the
Fault LED. Regardless of the cause, the switch requires immediate
attention.

Power
(green LED)

When lit, the switch is plugged in and the internal power supply is functional.

2 Gb/s
(green LED)

When lit, the switch is set to operate at a speed of 2 Gb/s. When off, the switch is
set to 1 Gb/s.

Switch
Operational
(green LED)

• When lit, indicates that the switch has completed initialization for ports with

inserted SFPs and that the switch is operational.

• When flashing, the switch has been configured for multiple zones, and one or

more zones are up with at least one zone down.

If no zones (excluding hard zones) are operational, the LED turns off.

Figure 2-4: System LEDs

Power

Switch Operational

Fault

2 Gb/s