Multiple switch zoning – Emulex 355 User Manual

Page 42

Advertising
background image

E

MULEX

M

ODEL

355 SAN S

TORAGE

S

WITCH

U

SER

S

G

UIDE

C

HAPTER

3: S

WITCH

M

ANAGEMENT

E

MULEX

C

ORPORATION

39

P

ART

N

UMBER

00041411-002 R

EV

. B

Multiple Switch Zoning

Zones can be configured across multiple switches using a similar procedure to a single switch. However,
multiple-switch zoning requires some coordination between the switches.

Building on the example for ports in multiple zones, move the devices onto two switches and have the
zones stretch between the two, as in

Figure 3-17

.

In

Figure 3-17

, zone 1 includes ports 2, 4, 5, and cascade port 1, while zone 2 includes ports 3, 5, 6, and

cascade port 1. Ports 1 (cascade port) and 5 are in both zones.

To configure multiple-switch zoning, do the following for each switch:

1.

Plan which ports should belong in each zone.

2.

From the One-Step Zoning page, select the appropriate ports for each zone.

Note: To ensure zone integrity when configuring multiple switch zoning, you must implement AL_PA

zoning through the Command Line Interface (CLI). See “AL_PA Zoning” on page 40 for additional
information.

Figure 3-17: Devices in Multiple Zones Across Multiple Switches

Figure 3-18: Zones Coordinated on Multiple Switches

Switch A

Switch B

Advertising