(Addr.

Hex)

Name

LCD Display

Description

Values

Page

L3-04

(0492)

Stall Prevention

Selection during

Deceleration

StallP Decel Sel

0: Disabled

1: General Purpose

2: Intelligent

3: StallP +Resistor

4: High Flux Brake

5: High Flux Brake2

0: Disabled. Deceleration at the active deceleration rate. An ov

fault may occur.

1: General purpose. Deceleration is paused when the DC bus

voltage exceeds the Stall Prevention level.

2: Intelligent. Decelerate as fast as possible while avoiding ov

faults.

3: Stall Prevention with braking resistor. Stall Prevention during

deceleration is enabled in coordination with dynamic braking.

4: Overexcitation Deceleration. Decelerates while increasing the

motor flux.

5: Overexcitation Deceleration 2. Adjust the deceleration rate

according to the DC voltage.

Note:

Setting 3 is not available in models 4A0930 and

4A1200.

Default: 1
Range: 0 to 5

<2>

184

L3-05

(0493)

Stall Prevention

Selection during Run

StallP Run Sel

0: Disabled

1: Decel Time 1

2: Decel Time 2

0: Disabled. Drive runs at a set frequency. A heavy load may

cause stalling.

1: Decel time 1. Uses the deceleration time set to C1-02 while

Stall Prevention is performed.

2: Decel time 2. Uses the deceleration time set to C1-04 while

Stall Prevention is performed.

Default: 1

Range: 0 to 2

185

L3-06

(0494)

Stall Prevention Level

during Run

StallP Run Level

Enabled when L3-05 is set to 1 or 2. 100% is equal to the drive

rated current.

Default:

<1>

Min.: 30%
Max.: 150%

<1>

186

L3-11

(04C7)

Overvoltage

Suppression Function

Selection

OV Inhibit Sel

0: Disabled

1: Enabled

Enables or disables the ov suppression function, which allows the

drive to change the output frequency as the load changes to

prevent an ov fault.

0: Disabled

1: Enabled

Default: 0

Range: 0, 1

L3-17

(0462)

Target DC Bus Voltage

for Overvoltage

Suppression and Stall

Prevention

DC Bus Reg Level

Sets the desired value for the DC bus voltage during overvoltage

suppression and Stall Prevention during deceleration.

Default: 375
Vdc

<3> <8>

Min.: 150
Max.: 400

<8>

L3-20

(0465)

DC Bus Voltage

Adjustment Gain

DC Bus P Gain

Sets the proportional gain for KEB Ride-Thru, Stall Prevention,

and overvoltage suppression.

Default:

<4>

Min.: 0.00

Max.: 5.00

L3-21

(0466)

Accel/Decel Rate

Calculation Gain

Acc/Dec P Gain

Sets the proportional gain used to calculate the deceleration rate

during KEB Ride-Thru, ov suppression function, and Stall

Prevention during deceleration (L3-04 = 2).

Default: 1.00

Min.: 0.10

Max.: 10.00

L3-22

(04F9)

Deceleration Time at

Stall Prevention during

Acceleration

PM Acc Stall P T

Sets the deceleration time used for Stall Prevention during

acceleration in OLV/PM.

Default: 0.0 s

Min.: 0.0

Max.: 6000.0

L3-23

(04FD)

Automatic Reduction

Selection for Stall

Prevention during Run

CHP Stall P Sel

0: Lv1 set in L3-06

1: Autom. Reduction

0: Sets the Stall Prevention level set in L3-04 that is used

throughout the entire frequency range.

1: Automatic Stall Prevention level reduction in the constant

output range. The lower limit value is 40% of L3-06.

Default: 0

Range: 0, 1

L3-24

(046E)

Motor Acceleration

Time for Inertia

Calculations

Mtr Accel Time

Sets the time needed to accelerate the uncoupled motor at rated

torque from stop to the maximum frequency.

Default:

<5> <6>

<7>

Min: 0.001 s

Max: 10.000 s

L3-25

(046F) Load Inertia Ratio

Load Inertia Rat

Sets the ratio between the motor and machine inertia.

Default: 1.0

Min.: 1.0

Max.: 1000.0

L3-26

(0455)

Additional DC Bus

Capacitors

ExtDC busCapSize

When DC bus capacitors have been added externally, be sure to

add those values to the internal capacitor table for proper DC bus

calculations.

Default: 0 μF

Min: 0

Max: 65000

L3-27

(0456)

Stall Prevention

Detection Time

Stl Prev DetTime

Sets the time the current must exceed the Stall Prevention level

to activate Stall Prevention.

Default: 50 ms

Min.: 0

Max.: 5000

L3-34

(016F)

Torque Limit Delay

Time

TRQ Dly Filter T

Sets the filter time constant in seconds for the torque limit value

to return to set value when the Power KEB Ride-Thru is enabled

(L2-29 = 1). If oscillation occurs during Power KEB Ride-Thru,

gradually increase this setting in increments of 0.010 s.

Note:

This parameter is not available in models 4A0930

and 4A1200.

Default:

<9>

Min.: 0.000

Max.: 1.000

B.8 L: Protection Function

316