Application Overview 2-17

Drive Monitoring

This section describes the network variables used to monitor the drive. Refer to the appropriate Technical Manual for additional information.

‹

Operating Status

The following table summarizes the network variables available for monitoring the drive’s operating status.

Table 2.21 – Operating Status

Index

Variable Name

Variable Type

Description

nv1

nviDrvSpeedStpt

SNVT_switch

Controls start/stop and a low resolution speed setpoint as a percentage of nciNmlFreq

nv2

nviDrvSpeedScale

SNVT_lev_percent Controls scaling for nviDrvSpeedStpt Negative values indicate reverse motor direction

nv3

nvoDrvCurnt

SNVT_amp

Reports output current

nv4 nvoDrvSpeed

SNVT_lev_percent

Reports

output

speed as a percentage of nciNmlFreq

nv5

nvoDrvVolt

SNVT_volt

Reports AC output voltage

nv6

nvoDrvPwr

SNVT_power_kilo Reports output power

nv7 nvoDrvRunHours

SNVT_time_hour

Reports accumulated run time

nv8 nviOpCommands SNVT_state

Controls the following operational commands:

„

bit 0 - External Fault (EF0)

„

bit 1 - Fault Reset

„

bit 2 - Multifunction Input 1 (terminal S3)

„

bit 3 - Multifunction Input 2 (terminal S4)

„

bit 4 - Multifunction Input 3 (terminal S5)

„

bit 5 - Multifunction Input 4 (terminal S6)

„

bit 6 - Multifunction Input 5 (terminal S7)

„

bit 7 - Reserved

nv9 nviReadParamNum SNVT_count

Requests a read of the specified drive parameter The response value is reported in

nvoReadParamVal

nv10 nviWriteParamNum SNVT_count

Requests a write of the specified drive parameter The write value is contained in

nviWriteParamVal

nv11

nviWriteParamVal

SNVT_count

Contains the value to be written to the drive parameter specified in nviWriteParamNum

nv12 nvoDrvStatus SNVT_state

Reports drive operational status:

„

bit 0 - Drive Running

„

bit 1 - Reverse Run Commanded

„

bit 2 - Drive Ready

„

bit 3 - Drive Faulted

„

bit 4 – Parameter Access Error

„

bit 5 – Multi-function Output 1

„

bit 6 – Multi-function Output 2

„

bit 7 – Reserved

„

bit 8 - Terminal S1 State

„

bit 9 - Terminal S2 State

„

bit 10 - Terminal S3 State

„

bit 11 - Terminal S4 State

„

bit 12 - Terminal S5 State

„

bit 13 - Terminal S6 State

„

bit 14 - Terminal S7 State

„

bit 15 - Reserved

nv13 nvoFltStatus SNVT_state

Reports drive fault status:

„

bit 0 - Overcurrent Ground Short Circuit

„

bit 1 - Overvoltage

„

bit 2 - Drive Overload

„

bit 3 - Overheat

„

bit 4 – Reserved

„

bit 5 – Fuse Blown

„

bit 6 – PID Feedback Lost

„

bit 7 - External Fault

„

bit 8 - Hardware Fault

„

bit 9 - Overload/Overtorque Fault

„

bit 10 – Excessive Speed Deviation

„

bit 11 - Undervoltage Fault

„

bit 12 – Undervoltage/Power Loss Fault

„

bit 13 – Input/Output Phase Loss

„

bit 14 – Drive Communication Loss

„

bit 15 – Operator Error

Advertising