B Transfer Setting for Project File Created Using MPE720 Ver.6

34

B Transfer Setting for Project File Created Using MPE720 Ver.6

To compress and transfer a project file (.ymw file) created using MPE720 Ver.6, set the transfer settings of the
MPLoader tool by the following procedure:

ΠThe MPLoader tool setting is possible for MPE720 Ver.6.02 or later.

1.

Start MPE720 Ver.6 and create a project file. Create the data to be transferred such as ladder
program, and store them in the project file.

Œ Refer to Engineering Tool for MP2000 Series Machine Controller: MPE720 Version 6 User’s Manual (SIEP

C880700 30) for information such as the procedure to start MPE720 Ver.6, to create a project file, and to edit
the ladder program.)

2.

Open the project file to be transferred. Select File - Environment Setting from the Main Manu. The
Environment Setting Dialog Box will be displayed.

3.

Select Transfer - MPLoader from the tree in the Environment Setting Dialog Box.

The detail setting window for the transfer using MPLoader tool will be displayed.

4.

Select the required items, and then click the OK Button.

Transfer Specification of Register data:

Select the check boxes of the registers to be transferred.

Clear the memory of Controller:

Select the Not clear the memory Option to overwrite the transferred data in the Machine Controller RAM.
Select the Clear the memory Option to clear the Machine Controller RAM before executing the automatic
transfer.

Transfer Specification of Others:

Backup the controller’s data before transfer Check Box:
Invalid for MPLoad Maker. Available only for MPLoader.
The flash saving is executed after transfer Check Box:
When this check box is selected, data is transferred from the Target PC to the Machine Controller and then
saved in the flash memory.

5.

Select File - Save Project or Save Project file as from the Main Menu to save the settings.

Advertising