10.3 Troubleshooting Malfunction Based on Operation and Conditions of the Servomotor

10-27

10

Trou

blesh

ooting

Abnormal Noise

from Servomotor

(cont’d)

Noise interference due to damaged
encoder cable.

Check if the encoder cable is bent
and the sheath is damaged.

Replace the encoder cable and cor-
rect the cable layout.

Excessive noise to the encoder
cable.

Check if the encoder cable is bun-

dled with a high-current line or near
a high-current line.

Correct the cable layout so that no
surge is applied.

The FG potential varies because of
influence from machines on the ser-
vomotor side, such as the welder.

Check if the machines are correctly
grounded.

Properly ground the machines to
separate from the encoder FG.

SERVOPACK pulse counting error

due to noise interference

Check if there is noise interference
on the I/O signal line from the
encoder.

Take measures against noise in the

encoder wiring.

Excessive vibration and shock to
the encoder

Check if vibration from the machine

occurred or servomotor installation
is incorrect (mounting surface accu-
racy, fixing, alignment, etc.).

Reduce vibration from the machine,
or secure the servomotor installa-

tion.

An encoder fault occurred.

Replace the servomotor.

Servomotor Vi-

brates at Fre-

quency of Approx.

200 to 400 Hz.

Unbalanced servo gains

Check to see if the servo gains have
been correctly adjusted.

Execute the advanced autotuning.

Speed loop gain value (Pn100) too
high.

Check the speed loop gain (Pn100).
Factory setting: Kv = 40.0 Hz

Reduce the speed loop gain
(Pn100).

Position loop gain value (Pn102)
too high.

Check the position loop gain
(Pn102).
Factory setting: Kp = 40.0/s

Reduce the position loop gain
(Pn102).

Incorrect speed loop integral time
constant (Pn101)

Check the speed loop integral time
constant (Pn101).
Factory setting: Ti = 20.0 ms

Correct the speed loop integral time
constant (Pn101).

Incorrect moment of inertia ratio
(Pn103)

Check the moment of inertia ratio
(Pn103).

Correct the moment of inertia ratio
(Pn103).

High Motor Speed

Overshoot on

Starting and Stop-

ping

Unbalanced servo gains

Check to see if the servo gains have

been correctly adjusted.

Execute the advanced autotuning.

Speed loop gain value (Pn100) too
high

Check the speed loop gain (Pn100).
Factory setting: Kv = 40.0 Hz

Reduce the speed loop gain
(Pn100).

Position loop gain value (Pn102)
too high

Check the position loop gain
(Pn102).
Factory setting: Kp = 40.0/s

Reduce the position loop gain
(Pn102).

Incorrect speed loop integral time
constant (Pn101)

Check the speed loop integral time
constant (Pn101).
Factory setting: Ti = 20.0 ms

Correct the speed loop integral time
constant (Pn101).

Incorrect moment of inertia ratio
data (Pn103)

Check the moment of inertia ratio
(Pn103).

Correct the moment of inertia ratio
(Pn103).

(cont’d)

Problem

Probable Cause

Investigative Actions

Corrective Actions

Advertising