CRC Control - Address = 0x53; NV Address = 0x08
The DTS Series protocol includes a Cyclic Redundancy Check on the
received packets to make sure that there are no errors. Any packets with
errors are discarded and not output on the UART. This feature can be
disabled if it is desired to perform error checking outside the module. Set
the register to 0x01 to enable CRC checking, or 0x00 to disable it. The
default CRC mode setting is enabled. Figure 26 shows examples of the
commands and Figure 27 shows the available values.

Transmit Wait Timeout - Address = 0x50; NV Address = 0x05
When a byte is received from the UART, the module starts a timer that
counts down every millisecond. The timer is restarted when each byte is
received. The value for this setting is the number of milliseconds to wait
before transmitting the data in the UART receive buffer. The default setting
for this register is 0x10 (~16ms delay).

If the timer reaches zero before the next byte is received from the UART,
the module begins transmitting the data in the buffer. This timeout value
should be greater than one byte time at the current UART data rate.

If the timeout value is set to 0x00, the transmit wait timeout is deactivated.
In this case, the transceiver waits until a number of bytes equal to the MTU
have been received by the UART. All of the bytes are sent once the MTU
has been reached. Figure 24 shows examples of the commands.

Network Group - Address = 0x51; NV Address = 0x06
Modules can be grouped into networks. Although only modules with the
same network group ID can communicate, modules in different network
groups but on the same RF channel still coordinate transmissions through
the CSMA mechanism. Valid values for this register are decimal 0 to
127. The default group setting is 0. Figure 25 shows examples of the
commands.

Figure 24: Transmit Wait Timeout Command and Response

Transmit Wait Timeout

Read Command

Read Response

Header

Size

Escape

Address

ACK

Address

Value

0xFF

0x02

0xFE

0x50

0x05

0x06

0x50

0x05

V1

Write Command

Header

Size

Address

Value

0xFF

0x02

0x50

0x05

V1

Figure 25: Network Group Command and Response

Network Group

Read Command

Read Response

Header

Size

Escape

Address

ACK

Address

Value

0xFF

0x02

0xFE

0x51

0x06

0x06

0x51

0x06

V1

Write Command

Header

Size

Address

Value

0xFF

0x02

0x51

0x06

V1

CRC Control Register Settings

V1

Mode

0x00

CRC Disabled

0x01

CRC Enabled

Figure 26: CRC Control Command and Response

Figure 27: CRC Control Register Settings

CRC Control

Read Command

Read Response

Header

Size

Escape

Address

ACK

Address

Value

0xFF

0x02

0xFE

0x53

0x08

0x06

0x53

0x08

V1

Write Command

Header

Size

Address

Value

0xFF

0x02

0x53

0x08

V1