Magnum Energy DC Breakers (BR-DC) User Manual

Page 2

Advertising
background image

High Capacity DC Breakers Instruction Sheet

2

© 2010 Magnum Energy, Inc.

Installation Steps:

1. Remove the breaker front panel cover

only after all power has been removed

from the Magnum Panel system.
2. Using a T25 screwdriver, remove only

the two #10-32 x 3.5” Torx screws that

attach the existing DC breaker to the

mounting plate and are adjacent to the

location that you will add your new DC

breaker (see Figure 2).
3. Place the new breaker against the

mounting plate adjacent to the existing

breaker; with one side of the new DC

breaker placed under the side where the

two mounting straps are loose.
4. While holding the new breaker in place,

attach two new mounting straps over the

new DC breaker. Ensure the holes on the

two new mounting straps – that are over

the existing DC breaker – line up with the

holes on the two existing mounting straps

(see Figure 3).
5. Insert the two Torx screws that were

removed in Step 2 into the aligned holes

of the new and existing mounting straps,

and tighten to secure the existing DC

breaker.
6. Insert two new #10-32 x 3.5” Torx

screws into the other side of the new

mounting straps and screw down enough

to hold the new DC breaker in place. Do

not fully tighten the screws, that will be

done in Step 7 after being aligned.
Note: The holes in the mounting plate - for

the Torx screws that hold the new breaker

- are NOT prethreaded. Use a power-driver

to screw these self-threading Torx screws

(T25 head) into the mounting plate.
7. Check the DC breaker alignment by

placing the front panel cover over the

DC breakers. If the fi t and alignment are

correct, tighten all Torx screws to secure

the new DC breaker. Note: Be careful not

to over-tighten and bend down the tabs

on the mounting straps.
The DC breaker is now installed. Connect

the inverter and battery cables with the

3/8-16 bolts/washers provided.

Le a v e

e x is ting

m ounting

s tra ps

(x 2)

in pla c e

M ounting P la te

(loc a tion for

ne w bre a k e r)

R e m ov e

s c re ws

a dja c e nt

to ne w

bre a k e r

loc a tion

Figure 2, Removing Screws

Figure 3, Install New Breaker

N e w

m ounting

s tra ps

(x 2)

E x is ting

m ounting

s tra ps

(x 2)

E x is ting

torx

s c re ws

(x 2 )

N e w

torx

s c re ws

(x 2 )

E x is ting

D C

bre a k e r

N e w

D C

bre a k e r

WARNING: During normal operation, the terminals, busbars, and

electrical components inside the MP enclosure may be energized

- DO NOT TOUCH. Disconnect all power sources before removing

the cover. Failure to take action could result in physical harm.