INT/LL switch

INT (internal) control switch

When the internal synchronization is used, set the switch to the INT side.

LL (Line-Lock) control switch

Matching the vertical synchronization with the power frequency is called the line-lock.

When two or more cameras are switched by the video switcher to a monitor TV, the vertical

sync. phase can be locked with the power frequency, and a stable vertical sync. is obtained

without being disturbed at the time of switching.

Line-lock is operative only when the AC 24V power supply is connected.

Caution:

1. The camera is synchronized to the power frequency of 60Hz 0.5Hz covering a

normal fluctuation of the power frequency. The camera may not compensate for

large fluctuation caused by power generated by an engine generator. etc.

2. It takes about 10 seconds or more to obtain a stable synchronization after the

power is turned on. This is necessary to stabilize the camera against the power

noise.

BLC (Back Light Control) switch

In case the back lighting is too bright to shoot the main object clearly, set this switch to ON

position.